Annual Fire Door Inspection Form
The most secure digital platform to get legally binding electronically signed documents in just a few seconds.
Annual fire door inspection form. Find out about fire and egress door inspection awareness programs and. Nfpa 80 requires both sides of swinging fire doors to be inspected and tested according to the following 13 items. Fire door field labeling and certification as defined in nfpa 252 or ul 10b c. Does the active door leaf completely close when.
Missing or incorrect fasteners. A visual inspection is required before testing to identify any damaged or missing parts that might create a hazard during testing. Annual fire door inspection checklist form nfpa 80. Krinkle fire door is a smart mobile app that guides inspectors to easily adhere to nfpa 80 standards speed up work and automate fire door reporting.
The 2012 edition of the life safety code nfpa 101 requires facilities to complete annual fire and smoke door inspection and testing. Annual fire door inspection form. Start a free trial now to save yourself time and money. Fire door assembly inspection checklist the 2007 and 2010 editions of nfpa 80 standard for fire do ors and other opening protectives section 5 2 inspections require all fire doors to be inspect ed not less than annually.
Fill out securely sign print or email your annual inspection of swinging fire door assemblies healthandwelfare idaho instantly with signnow. Door components need to be inspected and tested. Bottom flush bolts that do not project 1 2 into the strike. Watch a video overview of the annual fire door inspection initiative.
Annual inspection of fire and egress doors. Is the door undercut no more than inch. The system tracks customers buildings fire doors fire door frames and fire dampers as well as all associated inspections. Section 18 2 2 2 1 19 2 2 2 1 requires compliance with section 7 2 1 and section 7 2 1 15 2 requires compliance with nfpa 80 standard.
Inspection and testing form nfpa inspection and testing 1 of 4 alarm notification appliances and circuit information quantity êêêêcircuit style bells horns chimes strobes speakers other specify. Are the doors hinges frame hardware and threshold secure aligned and in working order with no visible signs of damage. Manual fire alarm boxes ion detectors photo detectors duct detectors heat detectors waterflow switches supervisory switches other specify. Annual fire door assembly inspection program to assist our industry as they conduct their annual inspections dhi has created an inspection report form and a model business agreement available to those who have successfully completed the fire door assembly inspection class.
13 points points fire doors inspection. Nfpa 80 requires that all fire door assemblies be inspected and tested yearly. Is the clearance from the door edge to the frame no more than 1 8 inch. Is the door free from missing or broken parts.
Available for pc ios and android.